| Ceiling System MF/2 Test Data |
|---|
| STRUCTURAL FLOOR - Timber |
| Test F96 |
| AIRBORNE 50dB DnTw + Ctr |
| IMPACT 48dB LnTw |
| Floor system was tested with an appropriate ceiling system |
| Please consult InstaCoustic before specifying an acoustic system. The structure has a bearing on the overall performance. |
Acoustic Suspended Ceiling System designed for use with timber floors.
The InstaCoustic MF/2FP suspended ceiling system incorporates acoustic hangers to isolate the framework from the structural soffit. This dramatically improves the airborne performance of the ceiling ensuring the best possible reduction of sound. Increased performance can be delivered by introducing the optional IN10 acoustic insulation quilt to the void created by the ceiling system.
Click the Steps below to view diagrams





| Acoustic Hangers Centres (mm) |
Primary Support Channel Centres (mm) |
Maximum Load Including weight of board (kg/m2) |
|---|---|---|
| 1200 | 1200 | 30 |
| 1200 | 900 | 40 |
| 1200 | 600 | 60 |
| 900 | 1200 | 35 |
Note: Acoustic hanger centres, please note that the first and last fixing from perimeter walls should be no more than 300mm