The 108 and 208 systems offer a high performance solution for both airborne and impact noise problems, with both timber and concrete floors, in the refurbishment or upgrade of existing dwellings, particularly where the floor height is a concern.
| Floor System 208 Test Data |
|---|
| STRUCTURAL FLOOR - Timber |
| Test F139 |
| AIRBORNE 49dB DnTw + Ctr |
| IMPACT 54dB LnTw |
| Floor system was tested with an appropriate ceiling system |
| Please consult InstaCoustic before specifying an acoustic system. The structure has a bearing on the overall performance. |
| Floor System 108 Test Data |
|---|
| STRUCTURAL FLOOR - Timber |
| Test F137 |
| AIRBORNE 54dB DnTw + Ctr |
| IMPACT 44dB LnTw |
| Floor system was tested with an appropriate ceiling system |
| Please consult InstaCoustic before specifying an acoustic system. The structure has a bearing on the overall performance. |
| System | Overlay Board mm |
Sound Barrier PADS mm |
Decoupling Fibre mm |
Overall Thickness mm |
Weight |
|---|---|---|---|---|---|
| 108 | 9 | 8 | 6 | 23 | 18 kg/m² |
| 208 | 9 | 13 | 6 | 28 | 28 kg/m² |