| Floor System IN19 Test Data |
|---|
| STRUCTURAL FLOOR - Timber |
| Test F126 |
| AIRBORNE 47dB DnTw + Ctr |
| IMPACT 54dB LnTw |
| Floor system was tested with an appropriate ceiling system |
| Please consult InstaCoustic before specifying an acoustic system. The structure has a bearing on the overall performance. |
The IN19P system, with its pre-bonded overlay board and decoupling fibre, comply with Robust Detail FFT5 and provide excellent sound insulation in new build constructions where a level concrete floor is present.
| System | Overlay Board (mm) | Decoupling Fibre (mm) | Overall Thickness (mm) | Weight |
|---|---|---|---|---|
| IN19P | 18 | 11 | 29 | 15 kg/m² |
Above weights & dimensions may be subject to slight variation
IN19P 18mm T&G Overlay Board (2.4 x 0.6m) pre-bonded with IN5 Decoupling Fibre
*System IN19P is suitable to receive vinyl floor coverings. When vinyl is to be laid, final preparation may be necessary to avoid the mirroring-through of the board joints. Please refer to vinyl manufacturers for further guidance.
Click the Steps below to view diagrams