Acoustic Batten (B40 & B60)

A range of acoustic batten floor systems which comply with Robust Detail FFT1 & FFT3. They are designed for use in new build constructions which have level concrete and timber floors.

Acoustic Performance

Floor System B40 & B60 Floor System B40 & B60
STRUCTURAL FLOOR – Timber STRUCUTURAL FLOOR – Concrete
Test No. L39 Test No. L20
AIRBORNE – 49dB Rw + Ctr AIRBORNE – 54dB Rw + Ctr
IMPACT – 52dB Lnw IMPACT – 49dB Lnw
Floor system was tested with an appropriate ceiling system Floor system was tested with an appropriate ceiling system
Please consult InstaCoustic before specifying an acoustic system. The structure has a bearing on the overall performance. Please consult InstaCoustic before specifying an acoustic system. The structure has a bearing on the overall performance.

Applications

  • Robust Detail FFT1 & FFT3
  • Pre-Completion Testing
  • New Build
  • Refurbishment / Material Change of Use
  • Timber Floor – Level
  • Timber Floor – Uneven
  • Concrete Floor – Level
  • Timber Frame
  • Access for Services
  • Downloads
  • Components
  • System Detail

Some text to explain components

Acoustic Battens

Acoustic Battens

Acoustic Insulation Quilt 60mm, 80mm or 100mm thick

Acoustic Insulation Quilt 60mm, 80mm or 100mm thick

18mm or 22mm Chipboard or Plywood

18mm or 22mm Chipboard or Plywood

Resilient Flanking Strip

Resilient Flanking Strip

Please click on an image to view product details.

System Detail Illustration

System Detail Illustration

Plan View: Typical Batten Layout

Plan View: Typical Batten Layout

Section Through Floor

Section Through Floor

System Weight (kg/m2)
B40 23
B60 25
Acoustic Batten Spacing
System Batten Size (mm)
Width x Depth
Batten Centres
(mm)
Chipboard or Plywood
(mm)
B40 43 x 45 400 18
43 x 53 400 18
43 x 70 400 18
B60 43 x 45 600 22
43 x 53 600 22
43 x 70 600 22