Acoustic Batten (B40 & B60)

A range of acoustic batten floor systems which comply with Robust Detail FFT1 & FFT3. They are designed for use in new build constructions which have level concrete and timber floors

Applications

  • Robust Detail FFT1 & FFT3
  • Pre-Completion Testing
  • New Build
  • Refurbishment / Material Change of Use
  • Timber Floor - Level
  • Timber Floor - Uneven
  • Concrete Floor - Level
  • Timber Frame
  • Access for Services

PDF Downloads

Acoustic Performance

Floor System B40 & B60 Floor System B40 & B60
STRUCTURAL FLOOR - Timber STRUCUTURAL FLOOR - Concrete
Test No. L39 Test No. L20
AIRBORNE - 49dB Rw + Ctr AIRBORNE - 54dB Rw + Ctr
IMPACT - 52dB Lnw IMPACT - 49dB Lnw
Floor system was tested with an appropriate ceiling system Floor system was tested with an appropriate ceiling system
Please consult InstaCoustic before specifying an acoustic system. The structure has a bearing on the overall performance. Please consult InstaCoustic before specifying an acoustic system. The structure has a bearing on the overall performance.

Components

  • Acoustic Battens
  • Acoustic Insulation Quilt 60mm, 80mm or 100mm thick
  • 18mm or 22mm Chipboard or Plywood
  • Resilient Flanking Strip

System Detail

Please click on an image to view product details
System Weight (kg/m²)
B40 23
B60 25

Acoustic Batten Spacing

System Batten Size (mm)
Width x Depth 
Batten Centres
(mm)
Chipboard or Plywood
(mm)
B40 43 x 45 400 18
  43 x 53 400 18
  43 x 70 400 18
B60 43 x 45 600 22
  43 x 53 600 22