IN19 & IN20

The IN19 and IN20 systems provide excellent acoustic insulation, particularly where an improved impact sound level is required. They are used in both new build and material change of use constructions where a level concrete floor is present.

Applications

  • Robust Detail FFT 5
  • Pre-Completion Testing
  • New Build
  • Refurbishment / Material Change of Use
  • Concrete Floor - Level
  • Restricted Floor Height

PDF Downloads

Acoustic Performance

Floor System IN19 Floor System IN20
STRUCTURAL FLOOR - Concrete STRUCTURAL FLOOR - Concrete
Test No. L45 Test No. F27
AIRBORNE - N/A AIRBORNE - 58dB DnTw + Ctr
IMPACT - 58dB Lnw IMPACT - 49dB LnTw
Floor system was tested with an appropriate ceiling system Floor system was tested with an appropriate ceiling system
Please consult InstaCoustic before specifying an acoustic system. The structure has a bearing on the overall performance. Please consult InstaCoustic before specifying an acoustic system. The structure has a bearing on the overall performance.

Components

  • 18mm or 22mm Chipboard with System IN19
  • Water Resistant T+G Overlay Board with System IN20
  • IN5 Decoupling Fibre
  • Resilient Flanking Strip (optional)

System Detail

Please click on an image to view product details
System Overlay Board
(mm)
Decoupling Fibre
(mm)
Overall Thickness
(mm)
Weight
(kg/m²) 
IN19 18 or 22 11 29 or 33 15
IN20 9 11 20 8